• Dé zakelijke webshop
  • Bel +32 3 870 80 28

Smart-UPS Vt Isx 30kva 400v W/4 Batt Modules Expandable To 5 W/ Pdu & Startup

Smart-UPS Vt Isx 30kva 400v W/4 Batt Modules Expandable To 5 W/ Pdu & Startup

Heeft u meerdere stuks nodig? Bel 03 870 80 28 of mail eShop@mobileaccess.be

Inleiding

APC Smart-UPS VT ISX 30kVA.

Features

Availability

  • Dual mains input
    • Increases availability by allowing the UPS to be connected to two separate power sources.
  • Scalable runtime
    • Allows additional run time to be quickly added as needed.
  • Hot-swappable batteries
    • Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Generator compatible
    • Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Automatic internal bypass
    • Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
  • Battery modules connected in parallel
    • Delivers higher availability through redundant batteries.

Serviceability

  • User-replaceable batteries
    • Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Battery replacement without tools
    • Provides reduced risk of load disruption by allowing quick and easy battery replacement.
  • Automatic self-test
    • Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Shippable with modules installed
    • Enables pre-installation UPS staging and testing and faster installation.
  • Modular design
    • Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Manageability

  • Network manageable
    • Provides remote management of the UPS over the network.
  • InfraStruXure Manager compatible
    • Enables centralized management via the APC InfraStruXure® Manager.
  • LCD display
    • Manage the UPS locally through a text-based display that allows quick diagnosis via stored alarm conditions and events.
  • Audible alarms
    • Provides notification of changing utility power and UPS conditions.
  • Programmable frequency
    • Ensures compatibility with different input frequencies.
  • LED status indicators
    • Quickly understand UPS status with indicators.
  • SmartSlot
    • Customize UPS capabilities with management cards.

Total Cost of Ownership

  • Input power factor correction
    • Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Temperature-compensated battery charging
    • Prolongs battery life by regulating the charge voltage according to battery temperature.
  • Manual maintenance bypass
    • Reduces installation costs by eliminating the need for an external mechanical bypass.
  • Intelligent battery management
    • Provides higher

Specifications

Output

  • Output Power Capacity
    • 24000 Watts / 30000 VA
  • Max Configurable Power
    • 24000 Watts / 30000 VA
  • Nominal Output Voltage
    • 230V,400V 3PH
  • Output Voltage Note
    • Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
  • Efficiency at Full Load
    • 96.40%
  • Output Voltage Distortion
    • Less than 5% at full load
  • Output Frequency (sync to mains)
    • 47 - 53 Hz for 50 Hz nominal
  • Crest Factor
    • Unlimited
  • Waveform Type
    • Sine wave
  • Output Connections
    • (1) Hard Wire 5-wire (3PH + N + G)
    • (12) IEC 320 C19

Input

  • Bypass
    • Built-in Maintenance Bypass,Built-in Static Bypass
  • Nominal Input Voltage
    • 400V 3PH
  • Input Frequency
    • 40 - 70 Hz (auto sensing)
  • Input Connections
    • Hard Wire 5-wire (3PH + N + G)
  • Input voltage range for main operations
    • 304 - 477V
  • Maximum Input Current
    • 41A
  • Input Breaker Capacity
    • 63A

Batteries & Runtime

  • Battery Type
    • VRLA
  • Included Battery Modules
    • 4
  • Available Battery Slots
    • 1
  • Typical recharge time
    • 3 hour(s)
  • RBC Quantity
    • 4
  • Typical Backup Time
    • at Half Load with 4 additional batteries
  • 310.2 minutes (12000 Watts)
    • Typical Backup Time
  • at Full Load with 4 additional batteries
    • 137.5 minutes (24000 Watts)
  • Runtime Chart
    • Smart-UPS VT
  • Extended Run Options
    • APC Smart-UPS VT ISX 30kVA 400V w/4 batt mod. exp. to 5, w/PDU & startup

Communications & Management

  • Pre-Installed SmartSlot Cards
    • AP9619
  • Control panel
    • Multi-function LCD status and control console
  • Audible Alarm
    • Audible and visible alarms : configurable delays
  • Emergency Power Off (EPO)
    • Yes

Physical

  • Maximum Height
    • 1995.00 mm
  • Maximum Width
    • 600.00 mm
  • Maximum depth
    • 1075.00 mm
  • Net Weight
    • 716.00 KG
  • Shipping Weight
    • 782.27 KG
  • Shipping Height
    • 1995.00 mm
  • Shipping Width
    • 600.00 mm
  • Shipping Depth
    • 1075.00 mm
  • Color
    • Black

Environmental

  • Operating Environment
    • 0 - 40 °C
  • Operating Relative Humidity
    • 0 - 95%
  • Operating Elevation
    • 0-999.9 meters
  • Storage Temperature
    • -50 - 40 °C
  • Storage Relative Humidity
    • 0 - 95%
  • Storage Elevation
    • 0-15000 meters
  • Audible noise at 1 meter from surface of unit
    • 67 dBA
  • Online Thermal Dissipation
    • 3685 BTU/hr
  • Protection Class
    • IP 20
.